Field Installable Fiber Optic Connector FC SC LC Easy / Quick Assemblies
Product Details:
Place of Origin: | China |
Brand Name: | FOCABLE |
Certification: | ISO Certificate, RoHS Compliant |
Model Number: | FC/UPC Fast Installable Connector |
Payment & Shipping Terms:
Minimum Order Quantity: | 100PCS |
---|---|
Packaging Details: | 100PCS/Bag |
Supply Ability: | 900000PCS/Month |
Detail Information |
|||
Connector Outer Diameter: | 3.0mm, 2.0mm, 0.9mm Or Drop Cable 3.0*2.0mm | Connector: | FC, SC, LC |
---|---|---|---|
Polishing Type: | UPC, APC | Cores: | Simplex |
Fiber: | SM, MM-OM1, MM-OM2, MM-OM3, MM-OM4 | Material: | Plastic Housing, Metal Housing |
High Light: | duplex fiber optic connector,simplex fiber optic connector |
Product Description
FC Field Installable Fast Connector For FTTH Cable and Indoor Patch Cable
Field installable Fast Connectors FC SC LC provide clean and professional terminations when creating hybrid solutions, or simply repairing a damaged fiber patch cable. These fast connectors use index matching gel as an internal mechanical grip to provide a clean and simple installation, without epoxy curing. All Field-Installable Connectors come color-coded for easy identification, such as aqua for Single-Mode, beige for OM1, black for OM2, Blue for OM3/OM4, and green for APC fiber specifications.
A complete Installation Kit for Field-Installable Connectors is also available, featuring all necessary equipment required for installing a variety of connectors. Each installation kit comes complete with Miller Clamp, tool of cable stripping, tool of guide rail, lint-free wipes, a fiber cleaver, buffer and Kevlar scissors, an Fiber Tester, and launch cables, all in a convenient carrying case. The Field-Installation Kit saves time and effort by completing repairs in under 1 minute!
Features
-
No internal mechanical splice
-
No epoxy and polish required
-
No tool and quick installation
-
Excellent insertion loss, 0.3dB max.
-
Visual inspection for proper installation
Applications
-
Fiber optic equipment
-
Fiber optic communication system
-
FTTH optic fiber terminal connection
-
Optical access network
-
Fiber optic data transmission
-
CATV
-
Central office connector replacement
-
Data center installation
Specifications
Insertion Loss | Average ≤ 0.2dB,Max ≤ 0.4dB |
Return Loss | UPC ≥ 40dB, 55dB typical at 25 degrees C + 5degrees APC ≥ 55dB, 60dB typical at 25 degrees C +/- 5degrees |
One-Time Assembly Yield | ≥ 97% |
Assembly Repeatability | ≥ 5 times |
Average Assembly Time | ≤ 3 minutes |
Life-Time | ≥ 30 years |
Tensile Strength | ≥ 30N(2.0x3.0 drop cable.) |
Operation Temperature | -40℃~+85℃ |
Field Installable Connector, Optical Fiber Fast Connector, Quick Fiber Connector, Field Installable Connector, Field Assembly Connector